Welltech SPCI2S Intel NetStructure SS7 Boards Manual do Utilizador Página 84

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 107
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 83
SS7 Programmers Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 84
5.5.3 Clock Event Indication
Synopsis:
Message issued by the board to indicate on-board clocking related events.
Message Format:
MESSAGE HEADER
FIELD NAME MEANING
type MVD_MSG_CLK_IND (0x0e23)
id
0
src MVD_TASK_ID
dst
0xdf
rsp_req
0
hclass
0
status event_id (see below)
err_info
Reserved for future use
len
0
Description:
This message is issued by the board to indicate events within the on-board
clocking circuitry.
Parameter Description:
event_id This field specifies the event that caused the indication to be generated:
event_id Description
1 PLL entered hold-over mode
Issued by boards acting as primary or secondary clock master when its nominated
clock reference becomes unavailable. The phase-locked-loop starts operating in
“hold-over” mode, continuing to generate an on-board clock at the same frequency as
the last valid reference signal.
2 PLL left hold-over mode
The nominated clock reference for a primary or secondary master board has become
available and the is now being used as the input to the board’s clock circuitry.
3 CT bus clock set A fail
The CT bus clock set A signals are not being correctly driven.
4 CT bus clock set A recover
The CT bus clock set A signals are being driven.
5 CT bus clock set B fail
The CT bus clock set B signals are not being correctly driven,
6 CT bus clock set B recover
The CT bus clock set B signals are being driven.
7 Master clock changeover
The card issuing this indication has automatically changed from secondary master to
primary master role for the clock set it was configured to drive.
Vista de página 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 106 107

Comentários a estes Manuais

Sem comentários