SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 66
Parameter Description:
The following table depicts which parameters are required for each of the seven
different modes. (* = parameter is required)
Mode Required Parameters
local st local ts source st source ts dest st dest ts pattern
1 * * * *
2 * * * *
3 * * * * * *
4 * *
5 * *
6 * *
10 * * *
11 * * * *
12 * * * *
If a parameter is not required it should be set to zero.
local_stream
The
local stream
defines which local stream to use for all the modes of
operation. The local streams are either an liu_id or a special identifier to allow
connection to the signalling processor as follows:
Local Stream Connected to
0 .. 7 liu_id 0 .. 7
131 (0x83) Signalling Processor
Refer to the User Manual for the board for more information on the board data
paths.
local_slot
The
local slot
defines which timeslot on the local stream to use for all the
modes of operation. The local slot value has the following valid ranges
depending on the type of local stream:
Local Stream type Local Slot range
Local stream to E1 LIU 1…31
Local stream to T1 LIU 1…24
Local stream to signalling processor 0…3